Metal detector

The GJ T series metal detector is currently the latest product in the field of metal detection in China. The latest metal detection technology, digital phase shifting and related detection technology, was adopted in the circuit design Stable performance, high detection sensitivity, and strong resistance to dryness.

Send Inquiry

Product Description

Technical parameter

Model Item Parameters

Adaptive

width (mm)

Response

belt

Sensitivity

≥mm

Overall dimensions (mm)
A B C D E F G
Standard type Heightened type Standard type Heightened type
GJT-5F 500 3.5

Φ 20 Iron

Aluminum balls

850 690 350 520 250 320 740
GJT-6F 650 1000 840 890
GJT-8F 900 1200 1010 1090
GJT-10F 1000 1400 1240 420 520 590 690 300 370 1290
GJT-12F 1200 1630 1470 470 570 640 740 1490
GJT-14F 1400 1830 1680 520 620 690 790 1730
GJT-16F 1600 2050 1890 570 670 740 840 1930
GJT-18F 1800 2280 2120 630 730 800 900 2190
GJT-20F 2000 2500 2340 680 780 850 950 2390

 

Scope of application:

GJT series of metal detector

The GJ T series metal detector is currently the latest product in the field of metal detection in China. The latest metal detection technology, digital phase shifting and related detection technology, was adopted in the circuit design Stable performance, high detection sensitivity, and strong resistance to dryness. Mainly used for manual fire bag color, cement, papermaking, mountain, forest, and cup protection In the belt conveyors of industries such as building materials, textile processing, and grain processing, they use the cross signal generated when metal enters the sensor electromagnetic field to process and drive the actuator (electromagnet, motor switch) through electronic technology, thereby eliminating harmful metals.

 

Features: Sensitivity debugging quantification: High sensitivity design can detect ultra large metal particles and sound and light alarms.

Detection range: aluminium Stainless copper, alloys, and other metals.

Timer function: Delay release after the appliance is turned on Time 1-10 seconds.

Control output: One pair of relay contacts is normally open, and the other pair is normally closed.

Installation method: The sensor is installed on the belt frame, and the amplitude of the belt frame should be less than 0.5mm. When the amplitude exceeds 0.5mm The sensor bracket should be installed separately.

Note: When the power supply voltage is unstable, a regulated power supply should be provided.